BSKGS - LPS ELECTRO CONTACT CLEANER, 00406

  • MSDS: BSKGS
  • Manufacturer: LPS LABORATORIES INC
  • Product Name: LPS ELECTRO CONTACT CLEANER, 00406
  • National Stock Number: 6850-00N047094
Product Identification

Product ID:LPS ELECTRO CONTACT CLEANER, 00406
MSDS Date:05/01/1993
FSC:6850
NIIN:00N047094
MSDS Number: BSKGS

Responsible Party
LPS LABORATORIES INC
4847 HUGH HOWELL ROAD
TUCKER, GA 30085-5052
US

Emergency Phone: 404-934-7800;700-424-9300(CHEMTREC)

Info Phone: 404-934-7800

Cage: 66724

Contractor
LPS LABORATORIES, INC.
TUCKER, GA 30085-5052 US

Telephone: 404-934-7800

Cage: 66724

Ingredients

ETHANE, 1,1,2-TRICHLORO-1,2,2-TRIFLUORO-;

CAS: 76-13-1

RTECS: KJ4000000

Fraction By Weight: 70-80%

OSHA PEL 1000 PPM;1250 STEL

ACGIH TLV: 1000 PPM;1250 STEL


METHANE, CHLORODIFLUORO-; (CHLORODIFLUOROMETHANE) (AEROSOL

CAS: 75-45-6

RTECS: PA6390000

Fraction By Weight: 20-30%

OSHA PEL 1000 PPM

ACGIH TLV: 1000 PPM

Hazards

LD50 LC50 Mixture:LD50: (ORAL,RAT) 43 G/KG
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL: RESP IRRIT.HIGH VAP CONCS CAN
LEAD TO DEPRESSION, WEAKNESS, VERTIGO, HEADACHE, DROWSINESS,
NAUSEA, VOMITING. IN SUSCEPTIBLE INDIVIDUALS, CARDIAC SENSITIZATION
CAN RESULT IN POTENTIALLY FATAL HE ARTBEAT IRREGULARITIES. EYE:
VAPOR AND LIQUID CAN IRRITATE EYES. SKIN: PROLONGED OR REPEATED
SKIN (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:CONTACT CAN CAUSE DEFAT & DRYING OF
SKIN. INGEST: A SINGLE DOSE IS PRACTICALLY NONTOXIC BY INGESTION.
CHLOROFLUOROCARBON MATLS HAVE PRODUCED SENSIT OF THE MYOCARDIUM TO
EPINEPHRINE IN LAB ANI MALS & COULD HAVE SIMILAR EFTS IN HUMANS.
ADRENOMIMETICS (E.G., EPINEPHRINE) MAY BE CONTRAINDICATED
EXCEPT(SUPP DATA)
Medical Cond Aggravated by Exposure:IN PERSONS WITH IMPAIRED
CARDIOVASCULAR FUNCTION, THE INHALATION OF VERY HIGH CONCENTRATIONS
MIGHT RESULT IN CARDIAC ARRHYTHMIA.

First Aid

First Aid:INHAL:REMOVE TO FRESH AIR. CALL MD. GIVE OXYGEN IF INDICATED.
EYE: FLUSH EYES W/PLENTY OF WATER FOR AT LEAST 15 MIN. IF IRRIT
PERSISTS, CALL MD. SKIN: WASH W/SOAP & WATER; APPLY MEDICATED SKIN
CREAM. INGEST: DO NOT INDUCE VOMIT. CONTACT MDIMMED. IF CONSCIOUS
GIVE 1-2 GLASSES OF WATER TO DRINK. NOTE TO MD: PRODUCT CAN CAUSE
CARDIAC MUSCLE SENSIT. DO NOT GIVE ADRENALINE OR SIMILAR
DRUGS.(SUPP DATA)

Fire Fighting

Flash Point Method:TCC
Flash Point:NONE
Extinguishing Media:AS APPROPRIATE FOR COMBUSTIBLES IN AREA.
Fire Fighting Procedures:FIRE FIGHTERS SHOULD WEAR NIOSH/MSHA APPROVED
PRESSURE DEMAND SCBA AND FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:INTENSIVE HEAT CREATED BY FIRE WILL CAUSE
AEROSOLS TO BURST. THERMAL DECOMPOSITION PRODUCTS MAY INCLUDE
CHLORIDES, FLUORIDES & PHOSGENE .

Accidental Release

Spill Release Procedures:EVACUATE AREA, VENT & AVOID BRTHG VAPS.
CONTAIN SPILL. REMOVE LEAKING CONTAINER AND TRANSFER PROD TO
ANOTHER VESSEL. CLEAN UP AREA BY MOPPING OR SOAK UP W/ABSORBENT
MATL. PLACE IN CLSD CNTNRS. DO NOT FLUSH TO SEWER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE AEROSOLS BELOW 120F AND ABOVE
32F. STORE ALL MATLS IN DRY, WELL-VENTILATED AREA. AVOID BRTHG
VAPS.
Other Precautions:PROLONGED CONTACT W/ALUMINUM PARTS IN A PRESSURIZABLE
FLUID SYSTEM MAY CAUSE VIOLENT RXNS. NO SMOKING IN AREA OF USE. DO
NOT USE IN GENERAL VICINITY OF ARC WELDING, OPEN FLAMES OR HOT
SURFS. HEAT &/OR UV RADIATION MAY CAUSE THE (SUPP DATA)

Exposure Controls

Respiratory Protection:NONE REQUIRED IF GOOD VENTILATION IS MAINTAINED.
IF VAPOR CONCENTRATION RISES ABOVE TLV, USE NIOSH/MSHA APPROVED
ORGANIC VAPOR CARTRIDGE. FOR LARGE SPILLS OR EMERGENCIES IN
COMPLETELY ENCLOSED AREAS, USE NIOSH/MSHA APPRVD SCBA.
Ventilation:VENTILATE LOW LYING AREAS WHERE VAPORS MAY COLLECT. PROVIDE
LOCAL EXHAUST IF TLV IS EXCEEDED.
Protective Gloves:SOLVENT RESISTANT GLOVES.
Eye Protection:FACE SHIELD OR GOGGLES.
Other Protective Equipment:AS NECESSARY TO PREVENT PROLONGED OR
REPEATED SKIN CONTACT.
Work Hygienic Practices:WASH HANDS W/SOAP & WATER AFTER USE AND/OR
BEFORE BREAKS, LUNCH AND AT THE END OF WORK PERIOD. REMOVE
CONTAM(SUPP DATA)
Supplemental Safety and Health
EFTS OF OVEREXP:FOR LIFE-SUSTAINING USES IN HUMANS ACUTELY OR
CHRONICALLY EXPOSED TO CFC'S . FIRST AID PROC: DO NOT ALLOW EXPOSED
PERSON TO EXERCISE VIGOROUSLY FOR 24 HRS. OTHER PREC: FORMATION OF
CHLORIDES, FLUORIDES &/OR PHOSGENE . HYGIENE PRACT: CLOTHING AND
LAUNDER BEFORE REUSE.

Chemical Properties

Boiling Pt:B.P. Text:117F,47C
Vapor Pres:270 @ 20C
Vapor Density:2.9
Spec Gravity:1.57 (H2O=1)
Evaporation Rate & Reference:1.7 (CCL4=1)
Solubility in Water:0.02 GM/100 GM
Appearance and Odor:CLEAR, COLORLESS LIQUID WITH SWEET ODOR.
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
REACTS VIOLENTLY WITH SODIUM, POTASSIUM, BARIUM METAL. REACTS W/FINELY
DIVIDED ALUMINUM, ZINC AND MAGNESIUM
Stability Condition to Avoid:AVOID CONTACT WITH OPEN FLAME, ELECTRIC
ARCS OR OTHER HOT SURFACES WHICH CAN CAUSE THERMAL DECOMPOSITION.
Hazardous Decomposition Products:THERMAL DECOMP MAY YIELD HALOGEN,
HALOGEN ACIDS, TRACE AMTS OF CARBONYL HALIDES. CHLORIDES, FLUORIDES
& PHOSGENE.

Disposal

Waste Disposal Methods:RECOVERED LIQ MAY BE SENT TO LICENSED RECLAIMER
OR INCINERATOR. CONSULT FEDERAL, STATE AND/OR LOCAL DISPOSAL
AUTHORITIES FOR APPROVED PROCEDURES.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.